One fleet, one console: fanless Thomas-Krenn hosts with XCP-ng at every site
Run identical fanless Thomas-Krenn hosts with XCP-ng at every branch or plant, managed, backed up and patched from your central Xen Orchestra.

The situation
An organization with many small branches or plants can run identical fanless Thomas-Krenn hosts with XCP-ng at each site, managed, backed up and patched from its central Xen Orchestra. Each site needs a few local VMs, such as a file service or a line application, that keep running on their own. One hardware model and one console let IT run every site like one estate.
How it works
- Standardize on one model for every site. LES network 6L V 5.0 fits most sites: Intel Core i5-1235U, up to 64GB RAM, 4x 2.5 Gbit/s plus 2x 10 Gbit/s SFP ports. LES plus V 4.0 fits smaller sites with up to 32GB RAM. Full specifications are on the Thomas-Krenn Low Energy Systems page.
- Install XCP-ng 8.3 LTS from a USB stick prepared with Rufus, Ventoy or dd, following the Thomas-Krenn wiki walkthrough.
- Add each site host to the central Xen Orchestra (XO), next to the datacenter pools.
- Run backup jobs with Vates VMS Backup from each site to a repository outside it, and apply updates to the fleet from XO.
What you get
- One console for every site. Inventory, backups and updates for the whole fleet run from the same XO as the datacenter.
- No fan to fail. Both models are fanless, so an unattended cabinet has no fan to replace.
- Room for the site's VMs and its uplink. LES network 6L V 5.0 takes up to 64GB RAM, with 10 Gbit/s SFP ports for the link to the datacenter.
- Site data protected off site. Each host has one drive bay of up to 7.68TB, and Vates VMS Backup keeps copies of its VMs in a central repository.
- The same tested box everywhere. Thomas-Krenn builds every system in Freyung and tests it before it ships.
Proof
Thomas-Krenn LES network 6L V 5.0 and LES plus V 4.0 with XCP-ng 8.3: not yet tested by Vates or Thomas-Krenn. Thomas-Krenn documents the XCP-ng installation in its public wiki (Installation of XCP-ng (external link, opens in a new tab)), written against the XCP-ng 8.3.0 image.
To plan a fleet, talk to Thomas-Krenn telephone consulting and compare models on the Thomas-Krenn low energy servers page (external link, opens in a new tab).
Requirements
- One LES network 6L V 5.0 or LES plus V 4.0 per site.
- XCP-ng 8.3 LTS installation media on a USB stick, prepared with Rufus, Ventoy or dd.
- Network reachability from each site to the central Xen Orchestra.
- A backup repository outside the sites for Vates VMS Backup.
Limitations
- One drive bay per host, up to 7.68TB: size VM storage within it and protect site VMs with backups to a central repository.
- Each site runs one standalone host: plan for local VMs that restart from backup rather than move to a second host.
- LES plus V 4.0 is rated for 0 to 40 °C: place it where ambient temperature stays in that range.